Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
In Vitro Assessment of Primary Stability of BoneTrust Sinus Implant Design
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 36 , Issue 5
September/October 2016

Pages 731–735


In Vitro Assessment of Primary Stability of BoneTrust Sinus Implant Design

Aydin Gülses, DDS, PhD/Mustafa Ayna, MSc, DDS, PhD/Hakan Güçlü, DDS/Metin Sencimen, DDS, PhD/M. Nabi Basiry, DDS, PhD/Matthias Gierloff, Prof Dr Rer Nat/Yahya Açil, MD, DDS, PhD


PMID: 27560678
DOI: 10.11607/prd.2562

The aim of this study was to analyze the primary stability of BoneTrust Sinus implants (BTSIs), which are intended to enable higher primary stability by their special design with reduced thread section in cases of reduced vertical bone availability, in comparison with standard BoneTrust implants (SBTIs) in vitro. A bone window 3 cm in length, 4 cm in width, and 3 cm in depth, resembling the maxillary bone window of the lateral sinus wall with 4 mm of residual bone height, was prepared at the dorsal side of freshly slaughtered bovine ribs. One single BTSI and a single SBTI with the same diameter (4 or 5 mm) were placed in each window. After implant placement, the implant stability quotient (ISQ) was measured by using resonance frequency analysis with an Osstell device. A total of 88 implants were placed. ISQ values varied between 63 and 84. Among the implants with 4-mm diameter, all BTSIs showed higher ISQ values compared with SBTIs. One-way analysis of variance showed a significant difference between BTSIs/SBTIs (P < .05). BTSIs with 4-mm diameter showed statistically higher values compared to BTSIs with 5-mm diameter (P < .05). Among the implants with 5-mm diameter, all SBTIs showed higher ISQ values compared to BTSIs but there was no significant difference. The use of 4-mm-diameter BTSIs could present higher ISQ values during simultaneous implant placement in conjunction with lateral sinus floor augmentation.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help